Data centres and IT

Fire protection engineered around uptime.

WATERWEB has protected technology campuses and a bank data centre with detection and gaseous suppression designed for critical equipment rooms.

Server rack aisle in a data centre

What is at stake

For a data centre, the threat of fire is inseparable from the threat of downtime. Fires in data centres are rare. When they do occur, often starting in uninterruptible power supply (UPS) and battery systems, the consequences for operators and their customers can be severe and lasting. Equally, a poorly engineered suppression system can itself cause an outage through accidental discharge.

The right approach combines very early warning, suppression that will not damage equipment, and meticulous engineering of every interface, so that the system acts decisively on a genuine fire and never on a false alarm. As India's data centre capacity expands, operators and tenants increasingly expect this standard as a baseline.

20%

of operators reported that their most recent significant outage cost more than US$1 million.

Source: Uptime Institute, Annual Outage Analysis 2026

Protected areas

The principal hazard in each area of the facility, and the protection WATERWEB applies to it.

AreaPrincipal hazardProtection
Data hallsElectrical fire in dense cabling and IT equipmentAspirating detection, clean-agent or inert-gas suppression
UPS and battery roomsLithium-ion thermal runaway and electrical fireEarly detection, gaseous suppression, compartmentation
Raised floors and ceiling voidsConcealed cable firesAspirating or point detection within voids
Electrical and generator plantSwitchgear faults, transformer oil and diesel firesDetection, suppression, transformer protection
Support areasOrdinary combustibles in offices, stores and loading baysPre-action or wet sprinklers, detection

Relevant systems

CO2 and clean-agent suppression

Total-flooding protection for generators, control rooms and server rooms.

Fire detection and alarm

Conventional and addressable fire alarm systems, and linear heat detection.

Sprinkler systems

Automatic sprinkler systems to IS 15105:2021 and, where specified, NFPA 13.

Annual maintenance contracts

Scheduled inspection, testing and code-referenced reporting throughout the year.

Regulatory context

Data centre fire protection is typically designed to the National Building Code (NBC) 2016 and the relevant Indian Standards, together with international standards such as NFPA 75 and NFPA 76 for information technology and telecommunications facilities, NFPA 2001 for clean agents, and the requirements of operators and their insurers.

Project record

Facilities in this sector for which WATERWEB has designed, installed or maintained fire protection systems.

  • Gannon Dunkerley & Co., State Bank of India data centreHyderabad
  • WiproBengaluru

Discuss your facility with our engineering team

Send us the details of your site and WATERWEB will arrange a survey and a proposal.

CallWhatsApp