Overview

Active systems suppress a fire; passive protection contains it. Fire-resisting walls, floors, doors and seals divide a building into compartments, limiting the spread of fire and smoke and protecting the escape routes on which occupants depend. Their performance is measured in time: the minutes for which a barrier maintains its stability, integrity and insulation.

Compartmentation is only as strong as its weakest penetration. Cables, pipes and ducts routed through fire walls after construction are among the most common causes of lost fire resistance, and they also undermine gaseous suppression by allowing agent to escape. WATERWEB treats firestopping as an engineered system, installed to tested details and documented for inspection.

Portable extinguisher discharged at a fire

How it works

Fire resistance is achieved by the complete assembly, not by individual products. A fire door is rated together with its frame, hinges, closer and hardware; a penetration seal is rated for the specific services that pass through it. Portable extinguishers provide the first response to a small fire and must be matched to the class of fire and positioned so that one is always within reach.

Key components

Fire-rated doorsets
Complete door assemblies tested for integrity and insulation.
Fire dampers
Close duct openings where ductwork passes through fire-rated construction.
Penetration firestopping
Seals, collars, pillows and mortars that restore the rating around services.
Cable coatings
Retard flame spread along cable runs in galleries and risers.
Portable extinguishers
Water, foam, powder, CO2, clean agent and wet chemical types.
Signage and registers
Identification, tagging and records for every item.

Extinguisher selection by fire type

Fire typeExtinguisher
Ordinary combustiblesWater, foam or multipurpose powder, for wood, paper, textiles and plastics.
Flammable liquidsFoam, powder, CO2 or clean agent.
Flammable gasesPowder, CO2 or clean agent, alongside isolation of the gas supply.
Combustible metalsSpecialised metal-fire powders.
Electrical equipmentCO2 and clean-agent extinguishers that do not conduct electricity.
Cooking oils and fatsWet chemical extinguishers for commercial kitchens.

Engineering considerations

Compartment strategy

Fire-resistance periods defined by the building's occupancy, height and escape design.

Tested details

Every product installed exactly as tested and certified, without substitution.

Service coordination

Penetration schedules agreed with electrical and mechanical contractors.

Extinguisher distribution

Type, rating and travel distance set in accordance with IS 2190:2024.

Inspection access

Seals and dampers installed so they can be inspected and tested.

Documentation

Certificates and registers ready for fire authority and insurer inspection.

Typical applications

  • Staircases, lift lobbies and refuge areas
  • Cable and service penetrations through walls and floors
  • Electrical rooms and cable galleries
  • All occupied buildings, for first-aid firefighting

Fire-resistance ratings and extinguisher types are determined by the space and the hazard.

Scope of delivery

  1. Survey

    Compartment walls, openings and existing fire ratings.

  2. Selection

    Rated doors, dampers, sealants and extinguisher types.

  3. Installation

    Doors, dampers and firestopping fitted to tested details and certified.

  4. Extinguisher servicing

    Inspection, recharging and hydrostatic testing.

  5. Records

    Tagging and a register entry for every extinguisher.

Owner responsibilities

Most inspection findings trace back to simple checks missed between service visits. The items below fall to the owner; every WATERWEB maintenance report adds the checks specific to the site.

  • Keep fire doors closed; never wedge them open
  • Keep extinguishers mounted, visible and unobstructed
  • Check extinguisher pressure gauges monthly
  • Seal any new penetrations through fire-rated walls

Frequently asked questions

How often do extinguishers require servicing?

IS 2190:2024 sets inspection, maintenance and hydrostatic test intervals by extinguisher type, along with a maximum service life. Each site's maintenance schedule lists the due dates for every unit.

Which extinguisher is required?

Selection depends on what could burn: ordinary combustibles, flammable liquids or gases, electrical equipment, metals or cooking oils. WATERWEB specifies the type and quantity for each area.

Planning a new facility, or assessing an existing system?

A WATERWEB engineer will review your drawings or survey the site, assess it against the governing code and set out recommendations in writing.