Government, defence and research
Specification-grade protection for facilities of national importance.
WATERWEB has protected missile launch centres for the Defence Research and Development Organisation (DRDO), launch pads for the Indian Space Research Organisation (ISRO) at Sriharikota and aircraft hangars for Hindustan Aeronautics Limited (HAL), as well as public-sector power stations and universities in Bengaluru.

What is at stake
Government, defence and research facilities house assets that are often irreplaceable: launch vehicles and spacecraft, missiles, military and civil aircraft, test and laboratory equipment, and archives. Their fire protection is procured against demanding specifications, delivered under close inspection and expected to perform for decades.
WATERWEB brings the discipline this work demands: compliance with Central Public Works Department (CPWD) specifications and tender conditions, rigorous documentation at every stage, and systems selected for the specific hazards of hangars, laboratories, stores and data rooms.
From the project record
- Defence Research and Development Organisation (DRDO)Missile launch centres
- Indian Space Research Organisation (ISRO)Sites across India
- ISRO, Satish Dhawan Space CentreSriharikota
- Hindustan Aeronautics Limited (HAL)Aircraft hangars
- NSC Projects, Air Force Hangar 6Bidar
Protected areas
The principal hazard in each area of the facility, and the protection WATERWEB applies to it.
| Area | Principal hazard | Protection |
|---|---|---|
| Launch pads and launch complexes | Propellant and fuel fires near high-value launch hardware | Deluge and water spray, foam, detection |
| Missile launch and test centres | Energetic materials and fuels near sensitive equipment | Detection, deluge, gaseous suppression |
| Aircraft hangars | Fuel spills beneath aircraft in large open volumes | Foam-water deluge, high-expansion foam |
| Laboratories | Flammable chemicals near sensitive equipment | Detection, gaseous suppression, sprinklers |
| Archives and records | Irreplaceable documents vulnerable to water | Early detection, clean-agent suppression |
| Control and data rooms | Electrical fire in critical electronic systems | Aspirating detection, gaseous suppression |
| Campus infrastructure | Inadequate fire water supply or fire service access | Hydrant ring mains, pump houses |
Relevant systems
Design and engineering
In-house computer-aided design (CAD), hydraulic calculations and tender documentation.
CO2 and clean-agent suppression
Total-flooding protection for generators, control rooms and server rooms.
Foam systems
Foam protection for flammable-liquid storage and fuel-handling areas.
Fire detection and alarm
Conventional and addressable fire alarm systems, and linear heat detection.
Fire hydrant systems
Internal wet risers, external hydrant networks, hose reels and fire pump installations.
Regulatory context
Government works are typically specified to the CPWD General Specifications, including Part V for wet riser and sprinkler systems, Part VI (2018) for fire detection and alarm, and Part VIII (2013) for gas-based systems, together with the National Building Code (NBC) 2016, the relevant Indian Standards and, for aircraft hangars, NFPA 409.
Project record
Facilities in this sector for which WATERWEB has designed, installed or maintained fire protection systems.
- Defence Research and Development Organisation (DRDO)Missile launch centres
- Indian Space Research Organisation (ISRO)Sites across India
- ISRO, Satish Dhawan Space CentreSriharikota
- Hindustan Aeronautics Limited (HAL)Aircraft hangars
- NSC Projects, Air Force Hangar 6Bidar
- University of Agricultural Sciences, GKVKBengaluru
Discuss your facility with our engineering team