End-to-end fire protection and engineering solutions · Pioneers since 1978

System fault or discharge? Emergency response

Government, defence and research

Specification-grade protection for facilities of national importance.

WATERWEB has protected missile launch centres for the Defence Research and Development Organisation (DRDO), launch pads for the Indian Space Research Organisation (ISRO) at Sriharikota and aircraft hangars for Hindustan Aeronautics Limited (HAL), as well as public-sector power stations and universities in Bengaluru.

GSLV launch vehicle on the launch pad at the Satish Dhawan Space Centre, Sriharikota

What is at stake

Government, defence and research facilities house assets that are often irreplaceable: launch vehicles and spacecraft, missiles, military and civil aircraft, test and laboratory equipment, and archives. Their fire protection is procured against demanding specifications, delivered under close inspection and expected to perform for decades.

WATERWEB brings the discipline this work demands: compliance with Central Public Works Department (CPWD) specifications and tender conditions, rigorous documentation at every stage, and systems selected for the specific hazards of hangars, laboratories, stores and data rooms.

From the project record

  • Defence Research and Development Organisation (DRDO)Missile launch centres
  • Indian Space Research Organisation (ISRO)Sites across India
  • ISRO, Satish Dhawan Space CentreSriharikota
  • Hindustan Aeronautics Limited (HAL)Aircraft hangars
  • NSC Projects, Air Force Hangar 6Bidar

Protected areas

The principal hazard in each area of the facility, and the protection WATERWEB applies to it.

AreaPrincipal hazardProtection
Launch pads and launch complexesPropellant and fuel fires near high-value launch hardwareDeluge and water spray, foam, detection
Missile launch and test centresEnergetic materials and fuels near sensitive equipmentDetection, deluge, gaseous suppression
Aircraft hangarsFuel spills beneath aircraft in large open volumesFoam-water deluge, high-expansion foam
LaboratoriesFlammable chemicals near sensitive equipmentDetection, gaseous suppression, sprinklers
Archives and recordsIrreplaceable documents vulnerable to waterEarly detection, clean-agent suppression
Control and data roomsElectrical fire in critical electronic systemsAspirating detection, gaseous suppression
Campus infrastructureInadequate fire water supply or fire service accessHydrant ring mains, pump houses

Relevant systems

Design and engineering

In-house computer-aided design (CAD), hydraulic calculations and tender documentation.

CO2 and clean-agent suppression

Total-flooding protection for generators, control rooms and server rooms.

Foam systems

Foam protection for flammable-liquid storage and fuel-handling areas.

Fire detection and alarm

Conventional and addressable fire alarm systems, and linear heat detection.

Fire hydrant systems

Internal wet risers, external hydrant networks, hose reels and fire pump installations.

Regulatory context

Government works are typically specified to the CPWD General Specifications, including Part V for wet riser and sprinkler systems, Part VI (2018) for fire detection and alarm, and Part VIII (2013) for gas-based systems, together with the National Building Code (NBC) 2016, the relevant Indian Standards and, for aircraft hangars, NFPA 409.

Project record

Facilities in this sector for which WATERWEB has designed, installed or maintained fire protection systems.

  • Defence Research and Development Organisation (DRDO)Missile launch centres
  • Indian Space Research Organisation (ISRO)Sites across India
  • ISRO, Satish Dhawan Space CentreSriharikota
  • Hindustan Aeronautics Limited (HAL)Aircraft hangars
  • NSC Projects, Air Force Hangar 6Bidar
  • University of Agricultural Sciences, GKVKBengaluru

Discuss your facility with our engineering team

Send us the details of your site and WATERWEB will arrange a survey and a proposal.

CallWhatsApp